Skip to main content Skip to search Skip to main navigation

Testomat 2000®

Product number: 100011
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "Testomat 2000®"

Testomat 2000 – Online Analysis Device for Water Hardness and Other Parameters

Continuous water quality monitoring with automatic titration and flexible parameter selection

The Testomat 2000 is a versatile analysis device for the continuous determination of key water quality parameters such as water hardness, carbonate hardness, p-value, and minus m-value. The process photometer operates fully automatically with a precise piston dosing pump and plain-text menu display, allowing measurement, analysis, and control without manual intervention. Individually selectable indicators enable different parameters and measurement ranges, while internal limit contacts ensure reliable monitoring and alarm functions.

Depending on the selected indicator, the device measures residual hardness, total hardness, carbonate hardness, p-value, or minus m-value fully automatically via precise titration. Two independently programmable limit contacts support automatic control and alarm functions, while external control options such as range-dependent measurement triggering or versions with SD card data logger are available for documentation and process analysis.

What functions does the Testomat 2000 from Heyl offer?

It combines modern measurement principles with practical control and evaluation functions. By selecting different indicator types, it can be used in a wide variety of applications. Two freely programmable limit values with adjustable hysteresis support monitoring tasks, and optional interfaces expand the device for complete data recording or integration with control systems.

Applications for the Testomat 2000 Hardness

  • Monitoring water quality in water treatment, blending, and drinking water systems
  • Monitoring and quality control of softening systems with or without blending
  • Monitoring and quality assurance of decarbonization systems
  • Prevention of acid intrusion in decarbonization systems
  • Boiler monitoring of steam boilers

Performance Profile of the Testomat 2000

  • Simple, menu-guided operation and programming via plain-text display
  • Measurement of residual hardness, total hardness, carbonate hardness, minus m-value, or p-value selectable via indicator choice
  • Free choice of hardness units: °dH, °f, ppm CaCO3, or mmol/l
  • High measurement accuracy due to precise piston dosing pump
  • Analysis triggering:
    • Automatic interval operation (interval pause adjustable from 0–99 minutes)
    • External triggering
    • Dynamic (exhaustion-dependent interval operation)
    • Quantity-dependent via contact water meter
  • Two independent limit values with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions
  • Monitoring of two measuring points (switching via external solenoid valves)
  • Internal error documentation
  • Programmable service address
  • Indicator volumes: 100 and 500 ml bottles
  • Programmable maintenance interval for maintenance requests

Weight

Weight 9,7 kg

Other attributes

Country of origin EU
Customs tariff number 90278990
Technical specifications
Power consumption: max. 30 VA
Protection class: I
Protection: IP 65
Ambient temperature: 10–45 °C
Water temperature: 10–40 °C
Dimensions (W x H x D):     380 x 480 x 280 mm
Operating pressure: 0,3–8 bar
Weight: approx. 9,5 kg
Menu Language: German, English, French, Polish, Dutch, Italian, Spanish
Measuring range: Water hardness: 0.89 - 448 ppm | Carbonate hardness: 8.9 - 358 ppm | p-value: 0.1 - 15 mmol/l | minus m-value: 0.05 - 0.5 mmol/l

Skip product gallery

We recommend our indicators, as well as the following accessories

Testomat® Indicator TH2005 500ml, bottle with product label and measuring range 0.05–0.50 °dH, water quality test
Testomat® indicator TH 2005, 500ml
Product number: 152005

Testomat Indicator TH2005 – Residual Hardness Measurement Original indicator for precise determination of residual hardness in water The Testomat Indicator TH2005 from Heyl, 500 ml, is an original measurement solution for determining residual hardness in water. The indicator ensures high measurement accuracy and reliability for daily use. Measurements are provided in standardized units (°dH, °f, ppm CaCO₃, and mmol/l). Order online now and benefit from a 3% discount in the online shop on Heyl products. The indicator is specifically designed for residual hardness monitoring in water treatment. It is suitable for continuous process control and stable water quality. Advantages of the Original Testomat TH2005 Indicator The Testomat Indicator TH2005 offers a wide range of benefits for reliable residual hardness monitoring in demanding applications: High accuracy in the low range: Specifically designed for precise determination of very low residual hardness from 0.05 to 0.50 °dH. Reliable color reaction: Clear and reproducible color changes allow secure monitoring of residual hardness. Versatile display units: Measurement in °dH, °f, ppm CaCO₃, and mmol/l – ideal for international and industrial applications. Optimal device compatibility: Precisely calibrated for the Testomat 2000 series, the new Testomat Limit from Heyl, and other compatible Testomat devices. Suitable for continuous operation: Designed for ongoing process control in water treatment, industry, and supply technology. Heyl original quality: Ensures proper device operation and retention of warranty and guarantee claims. Frequently asked questions How long does the indicator/reagent keep? The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months. How much indicator is used per analysis? When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.). The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis. By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator: Indicators - Consumption calculator - Heyl Neomeris What sizes are available for the bottles and is there anything to bear in mind? The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. To use 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming, and the screw cap with hole and insert for the indicator must also be purchased (item no. 40143). Where can I find the safety data sheet? The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads Safety Data Sheets. How can the indicator be disposed of? Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations. Can the indicator still be used after the expiry date? The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed. What is the optimum storage temperature for the indicator? Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C. Device warranty / guarantee Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.

€104.20*
Testomat Indicator TH2025 500ml Front view with white label, 500 ml bottle for measuring residual hardness in water
Testomat® indicator TH 2025 500ml
Product number: 152025

Testomat Indicator TH2025 – for Determining Residual Hardness Precise Residual Hardness Measurement with the TH 2025 for Testomat 2000 and Testomat Limit The Testomat Indicator TH2025 from Heyl is a chemical reagent solution for precise determination of residual hardness. It measures in various units (°dH, °f, ppm CaCO₃, and mmoI/I). Enjoy a 3% discount on Heyl products when ordering online in our HeylNeomeris Shop. With the TH2025 indicator, you can determine residual hardness in the range of 0.25 to 2.50 °dH. The 500 ml bottle provides a convenient dosing solution that can be used directly in the measuring device without any complex preparation. Where can the TH2025 Indicator be used? The indicator is suitable for: Testomat 2000 Testomat 2000 CAL Testomat 2000 DUO Testomat 2000 V Testomat 2000 self clean Testomat ECO Testomat ECO-PLUS Testomar EVO TH Testomat Limit What are the measurement ranges? 0.25–2.50 °dH, with a resolution of 0.05 0.45–4.48 °f, with a resolution of 0.10 4.48–44.8 ppm CaCO₃, with a resolution of 0.9 0.04–0.45 mmoI/I, with a resolution of 0.01 Frequently asked questions How long does the indicator/reagent keep? The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months. How much indicator is used per analysis? When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.). The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis. By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator: Indicators - Consumption calculator - Heyl Neomeris What sizes are available for the bottles and is there anything to bear in mind? The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. To use 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming, and the screw cap with hole and insert for the indicator must also be purchased (item no. 40143). Where can I find the safety data sheet? The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads Safety Data Sheets. How can the indicator be disposed of? Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations. Can the indicator still be used after the expiry date? The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed. What is the optimum storage temperature for the indicator? Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C. Device warranty / guarantee Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.

€104.20*
500ml bottle of Testomat® TH2100 with product label
Testomat® indicator TH 2100 500ml
Product number: 152100

Testomat Indicator TH2100 for Determining Elevated Residual Hardness Indicator solution for precise monitoring of residual hardness in the higher limit range 1.00–10.00 °dH The Testomat Indicator TH2100 from Heyl, 500 ml bottle, is an original indicator solution for determining residual hardness in the higher hardness range of 1.00–10.00 °dH in water treatment systems. The bottles are designed for use in Testomat devices and enable continuous and reliable monitoring. The TH2100 indicator is specifically designed for higher residual hardness levels. It supports safe process control in industrial and commercial water treatment systems. What measurement ranges does the TH2100 indicator cover? 1.00–10.00 °dH, resolution 0.20 1.79–17.9 °f, resolution 0.40 17.9–179 ppm CaCO₃, resolution 3.8 0.18–1.79 mmoI/I, resolution 0.04 Which Heyl Testomat devices is the indicator suitable for? The indicators are suitable for: Testomat 2000® Testomat 2000® CAL Testomat 2000® DUO Testomat 2000® V Testomat 2000® self clean Testomat ECO® Testomat ECO®-Plus Testomat® EVO TH Testomat Limit Frequently asked questions How long does the indicator/reagent keep? The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months. How much indicator is used per analysis? When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.). The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis. By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator: Indicators - Consumption calculator - Heyl Neomeris What sizes are available for the bottles and is there anything to bear in mind? The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. To use 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming, and the screw cap with hole and insert for the indicator must also be purchased (item no. 40143). Where can I find the safety data sheet? The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads Safety Data Sheets. How can the indicator be disposed of? Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations. Can the indicator still be used after the expiry date? The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed. What is the optimum storage temperature for the indicator? Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C. Device warranty / guarantee Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.

€107.70*