Product information "Horiba LAQUA WQ320-K - 2 channel professional measuring device for various parameters in analysis case"

Thank you for your interest in our smart and individually configurable measuring instruments of the HORIBA LAQUA WQ-300 series.

The high-quality digital multi-parameter handheld meters feature a large colour LCD display with LED backlight (7 cm x 5.2 cm), making them ideally suited for field use under a wide range of conditions and in direct daylight.

Use our configurator to select the appropriate measuring instrument from the HORIBA WQ-300 series with 1 to 3 measuring channels, the desired measuring parameters (sensor cartridges) and the required cable length according to your individual needs.

The sensor cables feature an integrated sensor receptacle and digital module. Additional measuring parameters can also be connected at a later stage using the corresponding sensor cable or carried in the measuring case as supplementary equipment.

As with other HORIBA handheld meters, the devices are particularly resistant to shocks, slipping and scratches thanks to their special rubber coating.

Operation requires four standard AA batteries with 2500 mAh. For greater flexibility during mobile use, the WQ-300 series can alternatively be powered by a power bank or battery pack via the integrated USB interface.

An IP67 certification, which confirms dust-tightness and protection against temporary immersion for up to 30 minutes at a water depth of one metre, completes the professional overall package alongside the ergonomic design and easy operation.

HORIBA offers a three-year warranty on the handheld measuring instruments of the LAQUA WQ-300 series.

Functions and Features

During measurements, users are supported by operating instructions displayed in the form of smiley symbols. These are complemented by an LED status indicator on the sensor to help prevent operating errors and implausible measurement results.

The small number of control buttons and the absence of complex, nested menus ensure that the instruments remain easy and safe to operate, even when used intermittently or by different users.

Additional Functions

  • Electrode wear indicator
  • Measurement stability indicator on the instrument and sensor
  • Hold function to "save" the current measured value on the display
  • Individual measuring point identification with up to 8 characters
  • Automatic calibration functions
  • Integrated sensor holders
  • Self-diagnostic function
  • GLP functions
  • Fold-out stand for convenient hands-free measurements
  • Transfer of measurement data to a computer or smartphone via USB or WiFi

Measuring Case for Mobile Use

All handheld meters of the WQ-300 series are supplied in a reinforced measuring case for mobile outdoor use.

The case provides space for the measuring instrument, electrodes and cables, as well as up to eight 60 ml bottles of buffer solutions.

An integrated holder for buffer solution bottles facilitates calibration.

Automatic Sensor Recognition

A particular advantage of the WQ-300 series is automatic sensor recognition through sensor cables with integrated digital sensor receptacles.

Information about the sensor, calibration data and measurement settings is stored in the digital sensor module and transmitted to the measuring instrument.

In addition, all connected sensors can be calibrated simultaneously, as each sensor module independently stores measurement and calibration data and transmits them to the WQ-300 series measuring instrument.

Analogue sensors can optionally be connected using the HORIBA BNC sensor adapter. Please contact us for further information.

Available Languages

  • German
  • English
  • French
  • Spanish
  • Portuguese
  • Chinese

Scope of Delivery

  • WQ-300 series handheld meter in a carrying case
  • Selected digital electrode, if applicable, and the corresponding sensor-specific cable with integrated digital sensor receptacle
  • Instruction manual

Manufacturer Article Number

  • WQ-320-K (2 channels): 3200832606

Calibrating the Instrument

pH Measurement

To obtain accurate results, a two-point calibration must be carried out. The following buffer solutions are recommended:

  • pH 7.00 and 4.01 for acidic samples
  • pH 7.00 and 10.01 for alkaline samples

If the expected pH value of the sample is unknown, a three-point calibration using pH 7.00, 4.01 and 10.01 is recommended.

It is recommended to begin calibration with pH 7.00.

Conductivity Measurement

For conductivity measurements, a single-point calibration is sufficient, for example at 1413 µS/cm.

For greater accuracy, a multi-point calibration can also be performed.

Important Note on the Chloride Sensor

Note: If a chloride sensor is selected, it is supplied without chloride ionic strength adjuster and chloride electrode filling solution.

These solutions must be purchased separately by the customer. The chloride sensor cannot be used without the required filling solution.

Note on Scope of Delivery: From November 2026, HORIBA products will be supplied without batteries. Existing stock may still include batteries. Batteries are no longer included with newly manufactured products and must be purchased separately if required.

Technical data
Digital pH Sensor Head with cable - pH / mV / Temp (°C/°F)

pH Range: -2.00 to 20.00 pH | -2.000 to 20.000 pH
Resolution: -2.00 to 20.00: 0.01 pH | -2.000 to 20.000: 0.001 pH
Accuracy: -2.00 to 20.00: ±0.01 | -2.000 to 20.000: ±0.005
Calibration Points: Up to 6
pH Buffer Groups : USA, DIN, NIST, NIST10, Custom
mV Range: ±1000.0 mV
Resolution: 0.1 mV
Accuracy: ±0.1 mV
Temperature Range: -30.0 to 130.0 °C | -22.0 to 266.0 °F
Resolution: 0.1 °C / °F
Accuracy: ±0.5 °C / ±0.9 °F
Calibration Option: Yes
Body Material: ABS / Polycarbonate
Length and Diameter: 85 x 30 mm
Connector: Push-pull
Cable Length: 
2 m (Model 300PH-2; Part No. 3200812206)
5 m (Model 300PH-5; Part. No. 3200812207)

pH Sensor Cartridge - pH/mV/Temp (°C/°F)
Model 300-P-C (Part No. 3200786363)

pH Range: -2.00 to 20.00 pH | -2.000 to 20.000 pH
Temperature Range: 0 to 80 °C | -32.0 to 176.0 °F
Junction Material: Porous sintered polyethylene
Double Junction: Yes
Temperature Sensor: Built-in
Length and Diameter: 110 x 16 mm
Body Material: Polycarbonate, glass bulb
 

Digital ORP Sensor Head with cable - ORP / Temp (°C/°F)
Model 300-O-2 (Part No. 3200812204)

ORP Range: -2000 to +2000 mV
Resolution: < ±1000.0 mV: 0.1mV | ≥ 1000.0 mV: 1 mV
Accuracy: < ±1000.0 mV: ±0.1 mV | ≥ 1000.0 mV: ±1 mV
Calibration Option: Yes
Temperature Range: -30.0 to 130.0 °C | -22.0 to 266.0 °F
Resolution: 0.1 °C / °F
Accuracy: ±0.5 °C / ±0.9 °F
Calibration Option: Yes
Body Material: ABS / Polycarbonate
Length and Diameter: 85 x 30 mm
Connector: Push-pull
Cable Length: 2 m

Digital Conductivity Sensor Head - EC / Sal / TDS / Res / Temp (°C/°F)

Conductivity Range:
μS/cm: 0.000 to 0.199 | 0.200 to 1.999 | 2.00 to 19.99 | 20.0 to 199.9 | 200 to 1999
mS/cm: 2.00 to 19.99 | 20.0 to 199.9 | 200 to 2000
μS/m: 0.0 to 19.9 | 20.0 to 199.9 | 200 to 1999 |
mS/m: 2.00 to 19.99 | 20.0 to 199.9 | 200 to 1999
S/m: 2.00 to 19.99 | 20.0 to 200.0
Resolution: Auto ranging, up to 4 significant digits
Accuracy: ± 0.5% full scale of each range | > 200 mS/cm (20.0 S/m): ± 1.5% full scale
Reference Temperature: 15 to 30°C
Temperature Coefficient: 0.00 to 10.00 %/°C
Calibration Points: Up to 4 (Auto) / Up to 5 (Manual)
Units: S/cm, S/m

Salinity Range:
0.00 to 80.00 ppt | 0.000 to 8.000 %
Resolution: 0.01 ppt, 0.001 %
Accuracy: ± 0.5% of reading or ± 0.01 ppt, whichever is greater
Salinity Curves: NaCl, Seawater (UNESCO 1978)
Calibration Option: Yes

Total Dissolved Solids (TDS) Range:
0.01 mg/L to 200,000 mg/L
Resolution: 0.01 minimum, 4 significant digits
Accuracy: ± 0.5% of reading or ± 0.1 mg/L, whichever is greater
TDS Curves: Linear (0.40 to 1.00), EN27888, 442, NaCl

Resistivity Range:
Ω•cm 0.1 to 199.9 | 200 to 1999
kΩ•cm 2.00 to 19.99 | 20.0 to 199.9 | 200 to 1999
MΩ•cm 2.00 to 19.99 | 20.0 to 200.0
Ω•m 0.001 to 1.999| 2.00 to 19.99 | 20.0 to 199.9 | 200 to 1999
kΩ•m 2.00 to 19.99 | 20.0 to 199.9 | 200 to 2000
Resolution: Auto ranging, up to 4 significant digits
Accuracy: ± 0.5% full scale of each range 
| > 200 mS/cm (20.0 S/m): ± 1.5% full scale

Temperature Range:
-30.0 to 130.0 °C-22.0 to 266.0 °F
Resolution: 0.1 °C / °F
Accuracy: ±0.5 °C / ±0.9 °F
Calibration Option: Yes
Body Material: ABS / Polycarbonate
Length and Diameter: 85 x 30 mm
Connector: Push-pull
Cable Length:
2 m (Model 300-C-2; Part No. 3200784468)
5 m (Model 300-C-5; Part. No. 3200812202

4-Cell Conductivity Sensor Cartridge
Model 300-4C-C (Part No. 3200780928)

Cell Constant: 0.172 cm-1
Conductivity Range: 10 μS/cm to 2000 mS/cm
Temperature Range: 0 to 100 °C|32.0 to 212.0 °F
Temperature Sensor: Built-in
Length and Diameter: 110 x 16 mm
Body Material: Epoxy, carbon 

Dissolved Oxygen Sensor DO - 
(mg/L, %) / O2 / Temp (°C/°F)

Dissolved Oxygen (DO) Range: 0.00 to 20.00 mg/L | 0.0 to 200.0 %
Resolution: 0.01 mg/L, 0.1%
Accuracy: ±0.2 mg/L, ±2 %
Salinity Compensation Auto: by conductivity sensor / Manual: 0.0 to 40.0 ppt
Barometric Pressure Compensation Auto: by built-in barometer / Manual: 10.0 to 199.9 kPa
Calibration Points: Up to 2
Oxygen Range: 0.0 to 50.0%
Resolution: >0.1%
Accuracy: ±0.5%
Temperature Range: -30.0 to 130.0 °C | -22.0 to 266.0 °F
Resolution: 0.1 °C / °F
Accuracy: ±0.5 °C / ±0.9 °F
Calibration Option: Yes
Body Material: ABS / Polycarbonate
Length and Diameter: 200 x 16 mm
Connector: Push-pull
Sensor cap: 1 included
Cable Length:
2 m (Model 300-D-2; Part No. 3200780940)
5 m (Model 300-D-5; Part. No. 3200780942)

Dissolved Oxygen Sensor Cap
Model 300-D-M (Part No. 3200781554)

DO Range: 0.00 to 20.00 mg/L | 0.0 to 200.0 %
Temperature Range: 0 to 50.0 °C | 32.0 to 122.0 °F
Length and Diameter: 10 x 16 mm
Body Material: PVC, PMMA

Digital Ion Sensor Head with cable - Ion / mV / Temp (°C/°F)
Model 300-I-2 (Part No. 3200812203)

Ion Range: (mg/L, mmol/L): 0.000 to 0.999, 1.00 to 9.99, 10.0 to 99.9, 100 to 999, 1000 to 9990, 10000 to 99900
Resolution: 0.001 minimum, 3 significant digits
Accuracy: ±0.1 mV
Calibration Points: Up to 5
mV Range: ±1000.0 mV
Resolution: 0.1 mV
Accuracy: ±0.1 mV
Temperature Range: -30.0 to 130.0 °C / -22.0 to 266.0 °F
Resolution: 0.1 °C / °F
Accuracy: ±0.5 °C / ±0.9 °F
Calibration Option: Yes
Body Material: ABS / Polycarbonate
Length and Diameter: 85 x 30 mm
Connector: Push-pull
Cable Length: 2 m

Generall functions:

  • Channel Single Dual Triple
  • Memory 10,000 Data with date and time stamp
  • Data Log Auto / Manual
  • Measurement Modes Auto Stable / Auto Hold / Real Time
  • Calibration Alarm Programmable: 0 to 400 days
  • Auto Power Off Programmable: 0 to 60 minutes
  • Real-time Clock Available
  • Sensor Status On display
  • Diagnostics Error codes
  • Language English, Japanese, French, German, Spanish, Portuguese, Chinese
  • PC Communication Via micro USB cable or wireless
  • Printer Communication Via 25-pin D-sub printer (RS232) cable
  • Meter Input Push-pull connector
  • Display Color graphic TFT-LCD, 3.5 inches
  • Housing IP67, shock & scratch resistant, non-slip (ABS / polycarbonate)
  • Power Requirement 4 x AA batteries / battery pack or USB charger with micro USB cable
  • Battery Life > 100 hours (with display brightness 3 and no sensor connected)
  • Dimensions 220 (L) x 90 (W) x 34 (H) mm
  • Weight Approx. 400g (batteries included), 320 g (batteries excluded)
  • Standard Accessories Carrying case, 4 x AA batteries, wireless SD card, manual, and quick guide

Available Models
WQ-310-K Part No. 3200832605 (1 Channel) 
WQ-320-K Part No. 3200832606 (2 Channel) 
WQ-330-K Part No. 3200832607 (3 Channel)
Skip product gallery

Other appliances in the Horiba LAQUA WQ300 series

Horiba LAQUA WQ310-K handheld meter with pH electrode, front view
Horiba LAQUA WQ310-K - 1 channel professional measuring device for various parameters in analysis case
Article number: 895750

Thank you for your interest in our smart and individually configurable measuring instruments of the HORIBA LAQUA WQ-300 series. The high-quality digital multi-parameter handheld meters feature a large colour LCD display with LED backlight (7 cm x 5.2 cm), making them ideally suited for field use under a wide range of conditions and in direct daylight. Use our configurator to select the appropriate measuring instrument from the HORIBA WQ-300 series with 1 to 3 measuring channels, the desired measuring parameters (sensor cartridges) and the required cable length according to your individual needs. The sensor cables feature an integrated sensor receptacle and digital module. Additional measuring parameters can also be connected at a later stage using the corresponding sensor cable or carried in the measuring case as supplementary equipment. As with other HORIBA handheld meters, the devices are particularly resistant to shocks, slipping and scratches thanks to their special rubber coating. Operation requires four standard AA batteries with 2500 mAh. For greater flexibility during mobile use, the WQ-300 series can alternatively be powered by a power bank or battery pack via the integrated USB interface. An IP67 certification, which confirms dust-tightness and protection against temporary immersion for up to 30 minutes at a water depth of one metre, completes the professional overall package alongside the ergonomic design and easy operation. HORIBA offers a three-year warranty on the handheld measuring instruments of the LAQUA WQ-300 series. Functions and Features During measurements, users are supported by operating instructions displayed in the form of smiley symbols. These are complemented by an LED status indicator on the sensor to help prevent operating errors and implausible measurement results. The small number of control buttons and the absence of complex, nested menus ensure that the instruments remain easy and safe to operate, even when used intermittently or by different users. Additional Functions Electrode wear indicator Measurement stability indicator on the instrument and sensor Hold function to "save" the current measured value on the display Individual measuring point identification with up to 8 characters Automatic calibration functions Integrated sensor holders Self-diagnostic function GLP functions Fold-out stand for convenient hands-free measurements Transfer of measurement data to a computer or smartphone via USB or WiFi Measuring Case for Mobile Use All handheld meters of the WQ-300 series are supplied in a reinforced measuring case for mobile outdoor use. The case provides space for the measuring instrument, electrodes and cables, as well as up to eight 60 ml bottles of buffer solutions. An integrated holder for buffer solution bottles facilitates calibration. Automatic Sensor Recognition A particular advantage of the WQ-300 series is automatic sensor recognition through sensor cables with integrated digital sensor receptacles. Information about the sensor, calibration data and measurement settings is stored in the digital sensor module and transmitted to the measuring instrument. In addition, all connected sensors can be calibrated simultaneously, as each sensor module independently stores measurement and calibration data and transmits them to the WQ-300 series measuring instrument. Analogue sensors can optionally be connected using the HORIBA BNC sensor adapter. Please contact us for further information. Available Languages German English French Spanish Portuguese Chinese Scope of Delivery WQ-300 series handheld meter in a carrying case Selected digital electrode, if applicable, and the corresponding sensor-specific cable with integrated digital sensor receptacle Instruction manual Manufacturer Article Number WQ-310-K (1 channel): 3200832605 Calibrating the Instrument pH Measurement To obtain accurate results, a two-point calibration must be carried out. The following buffer solutions are recommended: pH 7.00 and 4.01 for acidic samples pH 7.00 and 10.01 for alkaline samples If the expected pH value of the sample is unknown, a three-point calibration using pH 7.00, 4.01 and 10.01 is recommended. It is recommended to begin calibration with pH 7.00. Conductivity Measurement For conductivity measurements, a single-point calibration is sufficient, for example at 1413 µS/cm. For greater accuracy, a multi-point calibration can also be performed. Important Note on the Chloride Sensor Note: If a chloride sensor is selected, it is supplied without chloride ionic strength adjuster and chloride electrode filling solution. These solutions must be purchased separately by the customer. The chloride sensor cannot be used without the required filling solution. Why We Use These Measuring Devices in Water Treatment Precise calcium control is an important element of efficient water treatment, from drinking water purification and process water management to environmental analysis. Elevated calcium concentrations can contribute to scale formation, pipe damage, increased energy consumption and disruptions in chemical processes. For these applications, we offer configurable solutions from the HORIBA LAQUA WQ series in our online shop. Available Measuring Instruments WQ310-K: Single-channel solution for targeted measurements. WQ320-K: Simultaneous measurement of two parameters, such as calcium and conductivity. WQ330-K: Three-channel measurement for complex multi-parameter analyses. Benefits for Water Treatment Reliable measurement data for monitoring and optimising water treatment systems. Digital evaluation, documented measurement results and interfaces for data transfer. Robust design and practical measuring case for mobile on-site use. Flexible combination of calcium measurements with other parameters such as pH, conductivity or redox potential. Note on Scope of Delivery: From November 2026, HORIBA products will be supplied without batteries. Existing stock may still include batteries. Batteries are no longer included with newly manufactured products and must be purchased separately if required.

€485.00
Tip
Horiba LAQUA WQ‑330‑K handheld meter with three connected electrodes, front view, robust design.
Horiba LAQUA WQ330-K - 3 channel professional measuring device for various parameters in analysis case
Article number: 895752

Horiba WQ330-K – Your Professional 3-Channel Water Quality Meter Expandable multi-parameter system for simultaneous measurement of pH, conductivity, redox, and other water parameters The Horiba LAQUA WQ330-K is a powerful multi-channel device for advanced water analysis, both on-site and in the laboratory. With three freely configurable measurement channels, it can simultaneously record parameters such as pH, conductivity, redox potential, TDS, temperature, oxygen, ammonia, calcium, chloride, nitrate, fluoride, and potassium. Intuitive operation, automatic sensor recognition, and digital calibration ensure accurate, fast, and reproducible measurements. Flexible Multi-Parameter System for Field and Laboratory Applications The analysis kit with the Horiba WQ330-K is ideal for environmental and water body monitoring, research and teaching, as well as drinking and process water control. The large LCD display with LED backlight ensures excellent readability even in direct sunlight. Measurement data can be exported and documented via USB or wirelessly, greatly simplifying traceability and analysis. The modular system allows the device to be quickly and precisely adapted to any measurement task. It is ideal for users who need to efficiently and reliably monitor multiple water parameters. Technical Features and Key Advantages of the WQ330-K The three measurement channels of the Horiba WQ330-K enable simultaneous recording of different water parameters, reducing measurement time and allowing better evaluation of relationships between parameters. The modular sensor concept allows flexible use of digital sensors, which are automatically recognized and store their calibration history. Notably, the combination of high measurement precision, user-friendliness, and mobility makes this device stand out. Quick deployment without complicated setup, along with easy data transfer for documentation and analysis, makes the Horiba LAQUA WQ330-K an ideal solution for professional water analytics. Calibrating the instrument: pH measurement To obtain accurate results, a two-point calibration must be carried out. It is recommended that the following solutions be used: pH 7.00 and 4.01 for acidic samples pH 7.00 and 10.01 for alkaline samples Carry out a three-point calibration using pH 7.00, 4.01 and 10.01 if you do not know the expected pH value of the sample. It is recommended that you calibrate using pH 7.00 first. Conductivity measurement For a conductivity measurement, a single-point calibration is sufficient, for example at 1413 μS/cm. For greater accuracy, a multi-point calibration can also be carried out. Note: During the promotional period, the discount on accessories will be automatically deducted at the shop’s checkout when purchased together with the HORIBA WQ330 device. Note on Scope of Delivery: From November 2026, HORIBA products will be supplied without batteries. Existing stock may still include batteries. Batteries are no longer included with newly manufactured products and must be purchased separately if required. Frequently asked questions How long is the warranty period for HORIBA analysers? The warranty period is 2 years for the 300 (WQ) series and 1 year for the F series after delivery. Where can I find suitable replacement electrodes or buffer solutions? You can find the appropriate replacement electrodes and buffer solutions in the shop under the main item at the bottom of the cross-selling section. How do I clean the probe before calibration? The sensors should be cleaned with DI water (deionised). After cleaning, wipe them with tissue paper if possible. Frequently asked questions about the promotion How long does the promotion run for? The promotion runs from 1 September 2026 to 31 December 2026. How do I get the discount on the accessories? The discount will be automatically deducted at the shop’s checkout when you purchase the HORIBA WQ330 unit at the same time.

€468.00